————————————————— |  Technical Information thermomur | —————————————————

​

​

​

​

————————— |   WALL  | —————————

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

————————— |   CEILING  | —————————

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

​

————————— |   ROOF  | —————————

Normalelement

Type A1+A2/B1+B2

Thickwallelement

Type K1+K2

Insidewallelement

Type H1+H2 

Passivelement

Type L

Measure

Conrete

U-Value

Fire resistance

category

General

Linear measure

Height

Thickness of Insulation

Width

Volume

0,30 sqm. per element

0,25 mtr.

2 x 50mm

1 x 100 + 1 x 50mm

2 x 40mm

200mm

linear measure tolerance as slight as 5 cm

B25 or B15 concrete, up to 16,0 mm grain size,

K2 plastic consistency (38-40cm slump)

~136 ltr. per sqm. wall  (~150 ltr. with Type B1+B2)    

~65 ltr. per sqm. wall

———

DIN 4102

0,25 (V/sqm. mK)

0,20 (V/sqm. mK)

———

———

Type

​

———

Concretecore

150mm

70mm

———

0,25 mtr.

0,30 mtr.

0,15 mtr.

0,25 mtr.

Lenght

1,20 mtr.

Wallsurface

enclosure of space F 90

structural stability F 120

you can build 6,25 sqm wall per hour

per sqm. we need 3,3 Elementes

Roofelement

Type F

Measure

U-Value

General

Thickness of Insulation

With structural steel girders Bst 500/550, specifically designed to satisfy particular statics demands, rustproof and integrated intothe special Thermomur form units, made of EPS rigid foam or Styro concrete with different types of roof cladding.

0,36 sqm. per element

max. 170 mm

distance of the roof-beams 60cm 

0,20 V/sqm. mK)

Lenght/Width/Height

1,23 mtr. x 0,33 mtr. x 0,17 mtr.

Roofsurface

Inclination start with 30°

Available as wooden structures, specifically designed to satisfy particular statics demands, and as special Thermomur form unitsmade of hardly inflammable rigid foam, to serve as roof insulating slabs.

Ceilingelement

Type E

Measure

Concrete

U-Value

Thickness of Insulation

Volume of Beam

Type

0,125 sqm. per element

max. 180 mm

B25 or B15 concrete, up to 8,0 mm grain size, 

K3 plastic consistency (at least 50cm slump)

ca. 16,3 ltr. per running meter

Lenght/Width/Height

0,56 mtr. x 0,25 mtr. x 0,18 mtr.

Ceilingsurface

0,25 (V/sqm. mK)

Reinforced steel girders-steel type IV Bst 500/550 with very slight inherent load,

7 to 8m span, and up to 12m secondary reinforcemen

Steel plate girders with very slight inherent load, up to 12m span, and up to 18m secondary reinforcement.

Carrying capacity of such a construction amounts to approx. 5,5 KN/sqm.

If a floating screed flooring is used, this type of floor construction

can attain fire-resistance category F 90.

The footstep sound insulation with floating screed flooring, complies with the regulations specified in DIN 4109

General

© Copyright 2018, Maschinenfabrik Beaufort GmbH        | KontaktImpressum | Datenschutz |